- Check air inlet and filter for debris.
- Connect a test lamp to the two wires that run to pump and ensure that the lamp cycles on and off. Ensure that the lamp voltage and current requirements are the same as Accu-Flo™ coil voltage and current requirements.
- Make sure that the air-valve manual override (small red knob on front of valve) is switched to the "0" position.
- Check pilot pressure vent at the top of the operator/coil assembly to ensure that it is not clogged.
- Check for a worn out air valve. If air continually blows the exhaust in very large quantities, the air-valve seals may be worn beyond their ability to function properly. In this case, the valve must be replaced.
NOTE: Before the valve is scrapped, it is possible that it may be saved by completely disassembling the valve, cleaning all components and re-lubricating the valve.